THERMO E series
THERMO E 200
Parameter name |
Characteristis |
ECE permission number |
E1*2001 / 56*2006 / 119*0265*00 |
Implementation |
high pressure fuel pulverization |
Fuel type |
20 |
Rated heat emission (at
20°С temperature of environment), kV
|
diesel |
Fuel consumption, kg/h |
2,0 |
Rated voltage, V |
24 |
Operating voltage, V |
20,5…30 |
Consumed voltage (at 24 V), Wt |
55 |
Air temperature at heater input, °С |
-40... +85 |
Air temperature in heater compartment, °С |
-40... +85 |
Storage temperature, °С |
-40... +90 |
Operating presure of heat carrier, bar |
2.0 max. |
Heat exchanger capacity, l |
1,8 |
Min. fluid circulation, ± l/h |
2400 ± 200 |
Min. capacity of fluid circulation loop ,l |
25,0 min. |
Content of CO2 in exhaust
gases at rated voltage, V % |
10,3+0,4 (Euro 5) |
Overall dimensions of heater (± 3 mm), LхWхH, mm |
593 х 247 х 224 |
Weight, kg |
16,5 |
printable version